• 03 9312 6633
  • 03 9312 6433
  • MON - FRI FROM 8 AM TO 5 PM
Same Day Dispatch
RAYCHEM EPKT PAPER 22KV 1C HEATSHRINK TERMINATIONS OUTDOOR

RAYCHEM EPKT PAPER 22KV 1C HEATSHRINK TERMINATIONS OUTDOOR

Description

Over the last three decades, engineers in utilities and industry around the world have specified million’s of Raychem cable terminations at distribution voltages up to 36kV. Raychem terminations have become identified with reliability because of their unparalleled long-term performance – where it really counts – in the field. Today there are many changes influencing the distribution of power at medium voltages. For example, the transition to new types of polymeric cable, distribution at higher voltages, and the widespread usage of compact switchgear. Anticipating these industry changes, we have continued to extend and improve the product range, based on the extensive experience both in the field and at our outdoor test sites in polluted and desert environments. Now these developments are incorporated in a new generation of Raychem heat-shrinkable cable terminations, that are even easier to select and install, without compromising the reliability of proven materials technology. The improved system is simple to use, because the basic termination components and installation steps are the same – even if your network operates with voltages of 7.2 to 36kV; if you use 12kV belted paper cable and 24kV water-blocked single core polymeric cable; whether you make equipment connections in a cable box or in compact switchgear. Let’s review the main advantages of the improved system:
Universal Selection Procedure
• Simplified selection table allows quick selection based on conductor cross section and voltage class for either polymeric or MIND paper insulated cables (For MI draining oil cables, contact your local representative)
• Simple modification codes permit easy specification of optional accessory kits
• Enhanced range-taking ability means that one kit fits more conductor sizes, reducing stocking requirements
• Unlimited shelf life allows stocking of economic quantities without product spoilage
Simplified Cable Preparation
• Improved treatment of screen cut back is compatible with all state of the art screen removal techniques
• No tapering of insulation required
• No polishing of polymeric insulation surface
• No special preparation of sectored, or eccentric conductors, or of cable that is curved after unreeling from the cable drum
• Cable preparation steps are similar to those for Raychem joints

Enquiry Code Product Name Details Price
EPKT 24B 1MO
22KV 1C MIND OUTDOOR 25-50MM2 (SET OF 3 ENDS)
EPKT 24B 1MO

Details

  • Size:
    22KV 25-50MM2

Details

  • Size:
    22KV 25-50MM2
POA
Login For Price
EPKT 24C 1MO
22KV 1C MIND OUTDOOR 70-185MM2 (SET OF 3 ENDS)
EPKT 24C 1MO

Details

  • Size:
    22KV 70-185MM2

Details

  • Size:
    22KV 70-185MM2
POA
Login For Price
EPKT 24D 1MO
22KV 1C MIND OUTDOOR 240-300MM2 (SET OF 3 ENDS)
EPKT 24D 1MO

Details

  • Size:
    22KV 240-300MM2

Details

  • Size:
    22KV 240-300MM2
POA
Login For Price
EPKT 24E 1MO
22KV 1C MIND OUTDOOR 400-630MM2 (SET OF 3 ENDS)
EPKT 24E 1MO

Details

  • Size:
    22KV 400-630MM2

Details

  • Size:
    22KV 400-630MM2
POA
Login For Price
EPKT 24F 1MO
22KV 1C MIND OUTDOOR 800-1000M2 (SET OF 3 ENDS)
EPKT 24F 1MO

Details

  • Size:
    22KV 800-1000MM2

Details

  • Size:
    22KV 800-1000MM2
POA
Login For Price